Diagnosing GC2 Battery-Based Power Issues:

Diagnosing GC2 Battery-Based Power Issues:

If the GC2 does not remain powered on when not plugged directly into a power source.

  1. A battery issue may exist if the device immediately shuts off when not plugged into the AC adaptor.
  2. To begin, first confirm that the power adapter is working properly. The power adapter provided by Foresight Sports includes a green LED light that remains lit if properly receiving power. If the green light is not lit during operation, the adapter is not functioning properly. Please contact Foresight Sports Technical Support for a replacement adapter.
  3. If the power adapter is working properly, connect the device to AC power for 12 hours to recharge the battery. To check the current charge of the GC2 battery, using the LCD keypad on the display, press the left most arrow key and then navigate to the “About” menu screen within the display settings menu.The current battery charge will be displayed in volts. The GC2's Nickel Metal Hydride battery is considered fully charged at 7.6 volts and higher. The battery will need to be recharged if displays a reading of 7.1 volts or lower.
  4. If, after following the steps above, the device does not hold a charge when disconnected from the power supply, this indicates that the battery no longer holds a charge. Please contact Foresight Sports Technical Support for details on battery replacement.
    • Related Articles

    • User Initiated Battery Calibration Feature

      1.0 Introduction 1.1 Battery calibration loss symptoms In certain instances, the PLM’s battery can lose calibration causing some undesirable effects. The following observable symptoms may indicate a battery that has lost calibration: The battery ...
    • GC3 Power Supply Not Working

      If you have encountered an issue with your GC3 Power Supply you will want to follow the steps below. Issues with the GC3 Power Supply may present themselves as: 1. Battery Not Charging 2. Device Not Powering On 3. Device Abruptly Turning Off Shortly ...
    • GC2 Battery Care

      Please read through the GC2 Battery Announcement, which suggests a discharge/recharge at least once a month. Suggested Battery Care: 1. It is highly suggested to continue to cycle charge your GC2 battery every two-three weeks to maintain conditioning ...
    • Battery Care for the GCQuad

      Proper Battery Care The battery in your GCQuad has been designed to provide safe, reliable operation. However, the life of your GCQuad battery and its ability to hold an adequate charge is dependent upon a regular routine of fully discharging and ...
    • GC Product Network Trouble Shooting

      This guide is to assist with trouble shooting network issues from a device stand point. The network is required for the following: Subscriptions Device Registration Device Validation Purchased Feature Add-ons Region Confirmations Should you have an ...